For more information, visit www.fmiproducts.com
DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
NATURAL GAS
CHDV32NR
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference.
Flame
Flame
TM
Comfort
Comfort
by FMI PRODUCTS, LLC
P F S
®
US
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - DIRECT-VENT FIREPLACE

For more information, visit www.fmiproducts.comDIRECT-VENT FIREPLACEOWNER’S OPERATION AND INSTALLATION MANUALNATURAL GASCHDV32NR WARNING: If the infor

Page 2 - TAbLE OF CONTENTS

www.fmiproducts.com111986-01H10VENTING INSTALLATIONContinued WARNING: Do not recess vent termination into any wall. This will cause a re hazard.

Page 3

www.fmiproducts.com111986-01H 11VENTING INSTALLATIONContinuedFigure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff I

Page 4 - PRODUCT FEATURES

www.fmiproducts.com111986-01H12CORNER AND ALTERNATE INSTALLATIONRecommended Applications:• Corner ground oor installation• Ground oor installation

Page 5 - PREPARATION

www.fmiproducts.com111986-01H 13VENTING INSTALLATIONContinuedVenting with Two 90° ElbowsVertical (V) Horizontal (H1)Horizontal (H1) + Horizontal (H2)5

Page 6

www.fmiproducts.com111986-01H14INSTALLATION FOR VERTICAL TERMINATIONNote: Vertical restrictor must be installed in all vertical installations.1. De

Page 7 - LOCATION OF TERMINATION CAP

www.fmiproducts.com111986-01H 15 Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall str

Page 8

www.fmiproducts.com111986-01H16VENTING INSTALLATIONContinuedNote: Install restrictor into inner collar of replace as shown.Venting with Two 90° Elbow

Page 9

www.fmiproducts.com111986-01H 17PARTS LIST FOR VENTING KITS AND COMpONENTSFMI PRODUCTS, LLC Pipe & Vent KitsNumber DescriptionP47-6 6" Sect

Page 10 - VENTING INSTALLATION

www.fmiproducts.com111986-01H18FIREPLACE INSTALLATIONCHECK GAS TYPEUse proper gas type for replace unit you are installing. If your gas supply is no

Page 11

www.fmiproducts.com111986-01H 19FIREPLACE INSTALLATIONContinuedFigure 27 - Location of Wiring Diagram Decal (Model May Vary from Illustration)Wiring D

Page 12

www.fmiproducts.com111986-01H2SAFETy WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or prope

Page 13

www.fmiproducts.com111986-01H2011. Peel off backing paper and stick supplied wiring diagram decal on rebox bottom approximately 12" in fro

Page 14

www.fmiproducts.com111986-01H 21FIREPLACE INSTALLATIONContinuedFigure 31 - Gas ConnectionEquipment Shutoff Valve with 1/8" NPT Tap*3" Minimu

Page 15 - Continued

www.fmiproducts.com111986-01H22pRESSURE TESTING GAS SUppLY pIpING SYSTEM Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)1. Disconnect replace and

Page 16

www.fmiproducts.com111986-01H 23REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this replace with a broken glass door panel or without the

Page 17

www.fmiproducts.com111986-01H24Figure 38 - Removing/Replacing Glass DoorLockUnlockGlass FrameAssemblyScrewHingeLatchCleaning Glass DoorSee Cleaning an

Page 18 - INSTALLATION

www.fmiproducts.com111986-01H 259. Close glass door, lock door latches, replace screen and close louvers (see Removing/Replacing Glass Door, steps 5

Page 19

www.fmiproducts.com111986-01H2656Figure 45 - Installing Logs No. 5 and No. 64Figure 44 - Installing Log No. 4Ember MaterialFigure 46 - Placing Ember M

Page 20

www.fmiproducts.com111986-01H 274. Push in gas control knob slightly and turn clockwise to OFF.5. Wait ve (5) minutes to clear out any gas. Then

Page 21

www.fmiproducts.com111986-01H28OPERATIONContinuedMANUAL LIGHTING pROCEDURE1. Remove glass door (see Removing/Re-placing Glass Door, page 23).2. Foll

Page 22 - FIREPLACE INSTALLATION

www.fmiproducts.com111986-01H 29INSPECTING bURNERSCheck pilot ame pattern and burner ame patterns often.PILOT ASSEMBLYThe pilot assembly is facto

Page 23

www.fmiproducts.com111986-01H 3SAFETyContinueda coaxial pipe (pipe within a pipe and having the same center) venting system. It brings in fresh air fo

Page 24

www.fmiproducts.com111986-01H30 WARNING: Only parts sup-plied by the manufacturer should be used when replacing broken or damaged glass door panel

Page 25

www.fmiproducts.com111986-01H 31TROUbLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualied service person should service

Page 26

www.fmiproducts.com111986-01H32OBSERVED PROBLEMPilot lights but flame goes out when control knob is releasedBurner does not light after pi

Page 27 - OPERATION

www.fmiproducts.com111986-01H 33OBSERVED PROBLEMHeater produces a whistling noise when burner is litGlass sootsFireplace produces a clicking/tickin

Page 28

www.fmiproducts.com111986-01H34TROUbLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not

Page 29 - INSPECTING bURNERS

www.fmiproducts.com111986-01H 35SPECIFICATIONSREPLACEMENT PARTSNote: Use only original replacement parts. This will protect your warranty coverag

Page 30

www.fmiproducts.com111986-01H36PARTSMODEL CHDV32NR67211819101321220822-222-622-422-522-322-1114911171545163

Page 31 - TROUbLESHOOTING

www.fmiproducts.com111986-01H 37PARTSMODEL CHDV32NRThis list contains replaceable parts used in your replace. When ordering parts, follow the instruc

Page 32

www.fmiproducts.com111986-01H38PARTSBURNER ASSEMBLY MODEL CHDV32NR32113141815164578691210111719

Page 33

www.fmiproducts.com111986-01H 39PARTSBURNER ASSEMBLY MODEL CHDV32NRThis list contains replaceable parts used in your replace. When ordering parts, fo

Page 34

www.fmiproducts.com111986-01H4SAFETyContinued2. If you smell gas• shut off gas supply• do not try to light any appliance• do not touch any electrical

Page 35 - TECHNICAL SERVICE

www.fmiproducts.com111986-01H40NOTICE: All accessories may not be available for all replace models.Purchase these accessories from your local dea

Page 36 - MODEL CHDV32NR

www.fmiproducts.com111986-01H 41______________________________________________________________________________________________________________________

Page 37

www.fmiproducts.com111986-01H42_______________________________________________________________________________________________________________________

Page 38 - 111986-01H38

www.fmiproducts.com111986-01H 43______________________________________________________________________________________________________________________

Page 39 - NO. PART NO. DESCRIpTION QTY

111986-01Rev. H06/10WARRANTyKEEP THIS WARRANTyFMI PRODUCTS, LLC LIMITED WARRANTIESNew productsStandard Warranty: FMI PRODUCTS, LLC warrants this new p

Page 40 - ACCESSORIES

www.fmiproducts.com111986-01H 5Figure 2 - Common Fireplace LocationsFlush with a wallThrough exterior wall enclosed in a chaseCorner installation• Th

Page 41 - 111986-01H 41

www.fmiproducts.com111986-01H6PRE-INSTALLATION PREPARATIONContinuedFigure 4 - Framing Clearances for Installation Against an Exterior WallFigure 5 - F

Page 42 - 111986-01H42

www.fmiproducts.com111986-01H 7Figure 7 - Minimum Clearances for Termination CapLOCATION OF TERMINATION CAPFixedClosedOpenableFixedClosedVVVVVVVVXXVXG

Page 43 - 111986-01H 43

www.fmiproducts.com111986-01H8VENTING INSTALLATIONNOTICE: Failure to follow these in-structions will void the warranty. NOTICE: Do not seal terminatio

Page 44 - WARRANTy

www.fmiproducts.com111986-01H 9INSTALLATION pLANNINGThere are two basic types of direct-vent installation:• Horizontal Termination• Vertical T

Comments to this Manuals